Auto ELISA Processor (BIOBASE1000)

Kategori: ALAT LABORATORIUM | 20 Kali Dilihat
Auto ELISA Processor (BIOBASE1000) Reviewed by on . This Is Article About Auto ELISA Processor (BIOBASE1000)

①.2 microplates, 80 sample rack, 92 dilution rack. ②. 8 special reagent racks, 1 general reagent racks. ③. Biological safety protection provides the high level of operator and environmental protection. Model BIOBASE 1000 Sample Pipetting Unit Sample Rack  80 sample positions(tubes 12mm) Primary Sample Tubes 12*75mm Pipetting 10ul~1000ul, (100ul) CV<0.5% Dispensing System… Selengkapnya »

Rating: 1.0

Hubungi Kami

Order via SMS

6281327234498

Format SMS : ORDER#NAMA PRODUK#JUMLAH
Pemesanan Juga dapat melalui :
SKU :
Stok Tersedia
Kg
07-02-2019
Detail Produk "Auto ELISA Processor (BIOBASE1000)"

①.2 microplates, 80 sample rack, 92 dilution rack.

②. 8 special reagent racks, 1 general reagent racks.

③. Biological safety protection provides the high level of operator and environmental protection.

Model BIOBASE 1000
Sample Pipetting Unit Sample Rack  80 sample positions(tubes 12mm)
Primary Sample Tubes 12*75mm
Pipetting 10ul~1000ul, (100ul) CV<0.5%
Dispensing System 1 aspirating-dispensing probe with X-Y-Z movement; dilution system with a syringe of 1000ul, continuous flow washing station.
Reagent Pipetting Unit Reagent Racks 8 special reagent racks,1 general reagent racks
Removable Trays Modular racks to hold calibrators, controls and reagents for 8 test on line
Pipetting 10ul~1000ul,1ul stepping
Pipetting precision (100ul) CV<0.5%
Time to Dispense 4 minutes adding 96 reagents
Incubation Unit Incubators 2 independent units
Temperature Range RT to 45 °C
Temperature Accuracy ±0.5°C
Temperature Fluctuation ±0.5°C
Washing Unit Programmable Yes(options & parameters)
Wash Containers 2 wash buffers at 2.0L, with level-sensing
Washing System Two 8 nozzle manifolds, one to dispense and the other one to aspirate
Washing Residual <2μl
Reading Unit Reading System 8 independent photometric channels with mono and dichromatic reading capability
Photometric Range 0.000 ~3.000 OD
Spectral Range 400-700nm
Optical Filters 2 precision filters (450,630nm); 2 more on request (4 filters max, 400-700nm)
Software Unit Software System Windows 7/8/10 or above, LIS system available
Function Application Work list set up, patient reports and result filing; calibration curve storage for each carried out test
Data Reduction cut-off (qualitative)
Physical Specification Package Size(W*D*H) 1020*810*1240mm Gross Weight 160kg
Power Supply AC220V+10%,50/60Hz;110V+10%,60Hz; 500

 