BK-AA4530F Atomic Absorption Spectrophotometer

Kategori: ALAT LABORATORIUM | 5 Kali Dilihat
BK-AA4530F Atomic Absorption Spectrophotometer Reviewed by on . This Is Article About BK-AA4530F Atomic Absorption Spectrophotometer

Features: * Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional). * Integrated floated optical platform design improves the optical system shock resistance stable. * Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condition of the… Selengkapnya »

Rating: 1.0

Hubungi Kami

Order via SMS

6285292275599

Format SMS : ORDER#NAMA PRODUK#JUMLAH
Pemesanan Juga dapat melalui :
SKU :
Stok Tersedia
Kg
14-02-2019
Detail Produk "BK-AA4530F Atomic Absorption Spectrophotometer"

Features:

* Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional).

* Integrated floated optical platform design improves the optical system shock resistance stable.

* Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condition of the hollow cathode lamp.

* Position adjusting: the flame burner can be set on the best position automatically.

* Fully automated wavelength scanning and peak searching.

* Complete safety chains protection equipment: warning and automatic safety protection for the wrong burner connection, leakage of the gas, under voltage of air and the abnormal flameout.

* Deuterium lamp and self-absorption background calibration.

* Measuring method: flame absorption method and emission method.

* Result printing: parameter, data result and diagram.

* Data processing: more than 500 data self-storage and cut-off storage, the analyzed result is stored in EXCEL format.

Technical Parameters:

ModelBK-AA4530F
Wavelength Range190~900nm
Wavelength Accuracy±0.15nm
Wavelength Receptivity≤0.04nm
Base Line Stability≤0.002A/30min (Cu)
Characteristic Concentration0.02μg/ml/1% (Cu)
Detection Limit0.004μg/ml (Cu)
Measurement Repeatability≤0.5%
Grating1800 lines/mm
InflamerAll-metal titanium burner
AtomizerEfficient glass atomizer
Lamp stand8
D2 background CalibrationWhen the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method
Power Supply220V, 50/60Hz
Packing Size(mm)850*700*750(Main instrument)

950*620*1020(Accessories )

Gross Weight(kg)105Kg  (Main instrument)

100Kg   ( Accessories )

Standard AccessoriesPC workstation

HP inkjet printer

Oil free Air compressor

Acetylene reducing valve

Cu Hollow cathode lamp

Air filter

Optional AccessoriesGraphite Furnace

Hollow cathode lamp(Ag, Au, Ba, Ca, Cd, Cr ,Fe, Hg ,K, Li, Mg,Mn, Na, Ni, Pb, Zn, Sb,etc)

 
Chat via Whatsapp