Application: The unit is available for medical teaching, research, medical units for gastrointestinal X-ray spot film photography, remote control compartment, fluoroscopy and other Traumatic Radiography etc of X-ray routine examination, Can be used for  gastrointestinal imaging, cholangiography, Urinary tract imaging and Deep vein imaging and other imagings ; Can used… Selengkapnya »

Rating:

Hubungi Kami

Order via SMS

6285292275599

Format SMS : ORDER#NAMA PRODUK#JUMLAH
Pemesanan Juga dapat melalui :
SKU :
Kg
20-09-2018
Detail Produk "BT-XF06 High Frequency (Digital) X-ray System"

Application:
The unit is available for medical teaching, research, medical units for gastrointestinal X-ray spot film photography, remote control compartment, fluoroscopy and other Traumatic Radiography etc of X-ray routine examination, Can be used for  gastrointestinal imaging, cholangiography, Urinary tract imaging and Deep vein imaging and other imagings ; Can used for fluoroscopy of esophagus, breast, gastrointestine, Abdomen and limbs and spot film photography; Can do the operation of Fracture reduction and Taking foreign body from in vivo .

Features : 
1. Diagnostic table
·1)Visual display of man-machine interface, touch screen control, makes man-machine conversation more intuitive, convenient and easy to understand.
·2)Programmable controller technology, high control precision, good stability, excellent anti-jamming performance
·3)Inverter control technology, When the table move, it can soft start, soft stop, smooth no noise, more accurate positioning
·4)Reliable, high precision of angular displacement sensor technology, low dynamic noise, and long mechanical life.
·5)High-resolution of rotary encoders, high accuracy of auto-slice, security and stability.
·6)Rotation range of 90 ° ~ 0 ° ~ -25 °, can take routine examination of digestive organs , can also be used for a variety of special examination
·7)Humanized Design of diagnostic table lateral switch , near station positioning make the operation more convenient.
·8)Toshiba’s high-quality image intensifier, to further enhance image sharpness, contrast, more easily, to clearly identify Lesions.
·9)Move a wide range of spot film device, apply the operation fo People do not move with the operation of motor way easily to complete taking from the throat, esophagus,To the lower abdomen of a series of examinations .
·10)Spot film box open on their own, safe and reliable operation.
2. Generator
•1)With X-ray Radiography and perspective function of generator, maximum output power of 65 kW.
•2)Output voltage of 150 kV.
•3)With a smaller, lighter, modular design.
•4)In the exposure process, kV and mA can be adjusted to achieve a constant radiation output.
•5)Large-screen LCD flat panel used to display the APR conventional conditions and practical projects.
•6)User-friendly system configuration.
•7)Operator can modify the APR technology items.
•8)Provide APR /-ray tube data downloads.
•9)A variety of automated diagnostic procedures, and operators with prompts
.•10)With serial RS232 communication interface
•11)Operation can be individually programmed for the APR, and APR and manual techniques for programming options
•12)Programmable settings, calibration, and conduct regular APR (by connecting an external computer).
•13)For ABS (Automatic Brightness Stabilization) circuit select four kinds of kV and mA curve.

Specifications:

ItemContentTechnical parameter
Power supplyVoltage380V±38V
Frequency50Hz±1Hz
Capacity≥85kVA
internal resistor≤0.13Ω
Digital X-ray high voltage system (import high-frequency generator )

 

 Power Output65KW
 Inverter Frequency200kHz
photographyTube Voltage40kv—150kv step regulation
Tube Current10mA—800mA step regulation
Exposure time1.0s—6300ms step regulation
Control interfaceTouched LCD
fluoroscopyTube Voltage40kv—125kv step:2kv continuous regulation
Tube Current0.5mA—6mA continuous regulation
Automatic brightness for fluoroscopy IBSAutomatic brightness tracking,multiple settings beforehand
Digital Controlled X-ray Tube

(Toshiba, Japanese)

ModelE7252
Tube Focus:Large Focus/Small Focus1.2mm /0.6mm
Input PowerLarge focus:75kW  small focus: 27kW
thermal capacity210KJ
Rotary anode speed2700rpm
Micro-computer control digital tube remote diagnostic table

 

Material of the tabletop high strength、low absorb carbon fiber
Rotation of the table90°~0°~-25°
Transverse travel of table±110mm
Longitudinal travel of the photography holder and film spot device≥720mm
X-ray Focus—film gauge1100 mm—1500 mm
Rotating foot plate±360° rotation
Full film photography size8″×10″—14″×17″
Dividing method for spot filmFull film, half dividing, three parts dividing, four parts dividing
Control method for diagnostic tableRemote、table control、frequency conversion soft starting and stopping
beam limiterElectric Multi-leaf
Voice interactionTwo-way microphone system
fixed bucky device for tableGrid density: 103L/INCH, Grid ratio: 10:1,focusing distance: 120cm,fixed type: 15″×18″
Digital Image TV SystemImage IntensifierTOSHIBA integrated image intensifier with 400,000 pixels CCD camera (non-digital) / TOSHIBA 9” image intensifier and 1 mega pixels CCD camera (digital)
Monitor17〞medical high definition monitor, horizontal  central resolution ratio :1000 lines,fringe: 800 lines,video bandwidth: 12.5MHz,50bit,image number/second: 25 frame
Digital Picture Processing System

(CCU Sentinel)

High definition line by line output mode, 8 level noise reduction,store 8 image;LIH(freeze the last frame),the image can be turned vertically and horizontally,positive and negative image; OSD(monitor show)

 