Gas Chromatograph 2

Kategori: ALAT LABORATORIUM | 5 Kali Dilihat
Gas Chromatograph 2 Reviewed by on . This Is Article About Gas Chromatograph 2

Features: 1. 5.7-inch LCD display indicates temperature, time and gas flow. 2. Self-test, power protection, keyboard lock , automatic ignition and anti power mutation interference function. 3. Can connect with Internet, realize data transfer and program upgrade automatically. 4. Equipped with a flame ionization detector (FID), and TCD, ECD, FPD,… Selengkapnya »

Rating: 1.0

Hubungi Kami

Order via SMS

6285292275599

Format SMS : ORDER#NAMA PRODUK#JUMLAH
Pemesanan Juga dapat melalui :
SKU :
Stok Tersedia
Kg
12-02-2019
Detail Produk "Gas Chromatograph 2"

Features:

1. 5.7-inch LCD display indicates temperature, time and gas flow.

2. Self-test, power protection, keyboard lock , automatic ignition and anti power mutation interference function.

3. Can connect with Internet, realize data transfer and program upgrade automatically.

4. Equipped with a flame ionization detector (FID), and TCD, ECD, FPD, NPD are optional. Can install four detectors at the same time.

5. Can install packed column and capillary column at the same time

6. Double column compensation function, which can effectively restrain baseline drift and the influence of background noise.

7. Large capacity oven (300*280*180mm) can hold 2 pcs 0.32mm diameter capillary column (length: 80m).

8. Better thermal insulation effect: when the temp. of oven, vaporizing chamber and detector reach 300℃, the max. temp. of outer chamber is 40℃.

10. With chromatography workstation software to process data.

ModelBK-GC7820
OvenTemp. RangeRT~450℃
Temp. Accuracy≤±0.1℃
Temp. Program16-phase
Max. Temp. Heating Rate40℃/min
DetectorHydrogen Flame Ionization Detector (FID)Detection limit:≤3×10-12g/s

(Sample: n-hexadecane)

Baseline drift:≤1×10-13A/30min
Linear range:≥107
Thermal Conductivity Detector (TCD) (Optional)Sensitivity: >10000mv.ml/mg

(Sample: n-hexadecane)

Linear range:≥105
Electron Capture Detector (ECD) (Optional)Detection limit:≤1×10-14g/ml

(Sample: n-hexadecaneδ-666)

Linear range:≥103
Flame Photometric Detector (FPD) (Optional)Detection limit:≤2×10-11g/s (S of thiophene)

Detection limit:≤1×10-12g/s (P of methyl parathion)

Linear range (S):≥102

Linear range (P):≥103

Nitrogen and Phosphorus Detector (NPD) (Optional)Detection limit:≤1×10-12g/s (Azobenzene)

Detection limit:≤1×10-12g/s (Marla sulphur phosphorous)

Linear range:≥103
Power SupplyAC110/220V±10%, 50/60Hz
Standard AccessoryFID detector, Chromatography workstation software
Optional AccessorySample injection system, TCD, ECD, FPD and NPD detector, Chromatographic column.
Package Size (W*D*H)800*570*650mm