Gas Chromatography Biobase

Kategori: GC | 134 Kali Dilihat
Gas Chromatography Biobase Reviewed by on . This Is Article About Gas Chromatography Biobase

Control system: designed for monitoring and controlling the instrument via the computer. 1.Column Compartment/oven with superior thermal performance, multistage (10 ramps) programmed temperature control function. (supported by “control system”). 2.Advanced builtin data acquisition system , supporting real time instrument status monitoring,  detection signal acquisition and PC control. 3.Column oven accommodates up to 3 chromatographic columns, and supports quick heat‐up  and rapid cool‐down with automated back‐door opening. 4.Flexible sample introduction system: 3 sample injectors could be installed and operated simultaneously with independent temperature control. 5.High sensibility and stability detector. 6.2 independent and analog signals output. 7.Clarity software, compatible with GLP/FDA21 CFR Part11 requirements and regulations.  (electronic records and signatures). Model BK-GC1290 BK-GC1120 Description EPC(electronic  pneumatic  control) 7 inch touch screen display   Sample Introduction System sample injector and evaporation chamber       Column Oven Temperature  range Ambient temperature +7℃ ~ 400℃ (in 1℃ increment)   Temperature  accuracy ± 0.02℃   Cooling time 400℃ to 50℃ in 6 min at 25℃ ambient   Programmed  temperature setting 0.1℃~40℃/min (in 1℃ increment)   Program ramps 7 ramps in total (10 ramps available with control workstation①)   Flame Ionization Detector (FID) Detection limit ≤3×10‐12g/s (C16)   Drift ≤6×10‐13A/h Thermal  Conductivity Detector… Selengkapnya »

Rating: 1.0

Hubungi Kami

Order via SMS

6281327234498

Format SMS : ORDER#NAMA PRODUK#JUMLAH
Pemesanan Juga dapat melalui :
SKU :
Stok Tersedia
Kg
27-09-2018
Detail Produk "Gas Chromatography Biobase"

Control system: designed for monitoring and controlling the instrument via the computer.

1.Column Compartment/oven with superior thermal performance, multistage (10 ramps)

programmed temperature control function. (supported by “control system”).

2.Advanced builtin data acquisition system , supporting real time instrument status monitoring,

 detection signal acquisition and PC control.

3.Column oven accommodates up to 3 chromatographic columns, and supports quick heat‐up

 and rapid cool‐down with automated back‐door opening.

4.Flexible sample introduction system: 3 sample injectors could be installed and operated

simultaneously with independent temperature control.

5.High sensibility and stability detector.

6.2 independent and analog signals output.

7.Clarity software, compatible with GLP/FDA21 CFR Part11 requirements and regulations.

 (electronic records and signatures).

Model BK-GC1290 BK-GC1120
Description EPC(electronic  pneumatic  control)

7 inch touch screen display

 
Sample Introduction System sample injector and evaporation chamber
 

 

 

Column Oven

Temperature  range Ambient temperature +7℃ ~ 400℃

(in 1℃ increment)

  Temperature  accuracy ± 0.02℃
  Cooling time 400℃ to 50℃ in 6 min at 25℃ ambient
  Programmed  temperature setting 0.1℃~40℃/min (in 1℃ increment)
  Program ramps 7 ramps in total (10 ramps available

with control workstation①)

 

Flame Ionization Detector (FID)

Detection limit ≤3×10‐12g/s (C16)
  Drift ≤6×10‐13A/h
Thermal  Conductivity Detector

(TCD)

Sensitivity ≥5000mV.mL/mg
  Baseline noise ≤20μV
 

Flame Photometric Detector

(FPD)

Detection limit ≤8×10‐13g/s(P) ; ≤8×10‐11g/s(S)
  Drift ≤2×10‐11A/30min
  Baseline noise ≤5×10‐12A
 

 

Electron Capture Detector (ECD)

Detection limit ≤2×10‐13g/s  (γ‐666)
  Drift ≤80μV/30min
  Baseline noise ≤20μV
  Linear dynamic range ≥103
Nitrogen‐Phosphorus

Detector (NPD)

 

Detection limit

 

≤5×10‐13g/s(P) ; ≤5×10‐12g/s(N)

 
Chat via Whatsapp