High Performance Liquid Chromatography-BK3100

Kategori: ALAT LABORATORIUM » LAIN-LAIN | 10 Kali Dilihat
High Performance Liquid Chromatography-BK3100 Reviewed by on . This Is Article About High Performance Liquid Chromatography-BK3100

Features: Classic short strokeand multi-stage flow correction ensuring pump performance 2.Concave surface holographic grating and intelligent power supply for deuterium lamp steadily improving detector functioning 3.Self-developed PID control measure bringing true the accuracy of column oven temperature to 0.1℃ 4.The S3100 auto-sampler capable of greatly improving instrument automaticity and matching with a… Selengkapnya »

Rating: 1.0

Hubungi Kami

Order via SMS

6285292275599

Format SMS : ORDER#NAMA PRODUK#JUMLAH
Pemesanan Juga dapat melalui :
SKU :
Stok Tersedia
Kg
13-02-2019
Detail Produk "High Performance Liquid Chromatography-BK3100"

Features:

  1. Classic short strokeand multi-stage flow correction ensuring pump performance

2.Concave surface holographic grating and intelligent power supply for deuterium lamp steadily improving detector functioning

3.Self-developed PID control measure bringing true the accuracy of column oven temperature to 0.1℃

4.The S3100 auto-sampler capable of greatly improving instrument automaticity and matching with a variety of HPLC systems

5.Application of optoelectronic isolation and EMI protection ensuring stable communication

6.All-round upgraded workstation that is operator-friendly and promotes customer experience

Technical Parameters:

ModelBK-LCI3100BK-LCGH3100BK-LCQL3100
High Pressure Constant Flow PumpQuantity1 Set2 Set1 Set
Flow Rate Range0.001mL/min-10.000mL/min
Flow Accuracy≤±0.2% (1.00ml/min, H2O,R.T.,8.5MPa)
Flow PrecisionRSD≤0.075% (1.00ml/min, H2O,R.T.,8.5MPa)
Maximum Pressure45MPa
Pressure accuracy≤±3.0%
Pressure pulsation≤0.1MPa
 

 

 

 

UV/VIS

Detector

Wavelength Range190-700nm
Wavelength Repeatability≤0.1nm
Wavelength Accuracy≤±1.0nm
Band Width8nm
Response Time0.0s-5s
Baseline Noise≤±0.5×10-5AU
Drift≤1.0×10-4AU/h
Path length10 mm(analytical cell)
Light SourceDeuterium Lamp
Low-Pressure Gradient UnitIntegrated vacuum degasser//4 channel
Composition Rang0-100%
Composition Precision≤0.2% RSD
Composition Accuracy≤±2.0%
Data-processing Workstation◆ Internal and external standard calculation methods

◆ Automatically displays, prints, exports and starts other programs after the completion of a measurement.

◆ Comply with the requirements of the 21 CFR Part 11 directive of the FDA

3100 System Kits1 Set
Power SupplyAC110/220V±10%, 50/60Hz
Optional AccessoryColumn Oven, Autosampler, Degasser, Diode Array Detector, Refractive Index Detector, Evaporative Light Scattering Detector, Fluorescence Detector

 