High Performance Liquid Chromatography-BK5100

Kategori: ALAT LABORATORIUM » LAIN-LAIN | 15 Kali Dilihat
High Performance Liquid Chromatography-BK5100 Reviewed by on . This Is Article About High Performance Liquid Chromatography-BK5100

Features: High pressure constant flow pump with parallel pump heads and optimized 5mm stroke of plunger rod ensuring perfect pump performance 2.The higher level of integration with binary or quarternary pumps integrated into one set of module 3.Specially designed column oven for GPC, which represents greater capacity of three columns, max… Selengkapnya »

Rating: 1.0

Hubungi Kami

Order via SMS

6285292275599

Format SMS : ORDER#NAMA PRODUK#JUMLAH
Pemesanan Juga dapat melalui :
SKU :
Stok Tersedia
Kg
13-02-2019
Detail Produk "High Performance Liquid Chromatography-BK5100"

Features:

  1. High pressure constant flow pump with parallel pump heads and optimized 5mm stroke of plunger rod ensuring perfect pump performance

2.The higher level of integration with binary or quarternary pumps integrated into one set of module

3.Specially designed column oven for GPC, which represents greater capacity of three columns, max ID10×250mm.

4.Adoption of advanced UDP communication protocol that is fast, stable and can be used for instrument remote control

5.Equipped with W5100 data system match fully the FDA 21CFR Part 11

6.The HPLC system being more integrated and intelligent

Technical Parameters:

Model BK-LCI5100 BK-LCG5100 BK-LCQL5100
 Pump Type Isocratic Pump Gradient Pump Quarternary Low Pressure Pump
Flow Rate Range 0.001-10.000mL/min, in 0.001mL increments
Flow Accuracy ≤±0.2% (1.00ml/min, H2O,R.T.,8.5MPa)
Flow Precision RSD≤0.06% (1.00ml/min, H2O,R.T.,8.5MPa)
Maximum Pressure 63MPa
Pressure accuracy ≤±3.0%
Pressure pulsation ≤0.1MPa
Composition rang / 0-100% 0-100%
Composition precision / ≤0.2%RSD ≤0.3%RSD
 

 

 

 

UV/VIS

Detector

Wavelength Range 190-800nm
Wavelength Repeatability ≤0.1nm
Wavelength Accuracy ≤±1.0nm
Band Width 6nm
Response Time 0.0s-5s
Baseline Noise ≤±0.25×10-5AU(empty cell, 254nm, 1.0s)
Drift ≤0.5×10-4AU/h(empty cell, 254nm, 60min)
Path length 10 mm(analytical cell)
Light Source Deuterium Lamp and Tungsten Lamp
Data-processing Workstation ◆ Sequence tables for any set of samples

◆ Internal and external standard calculation methods

◆ Automatically displays, prints, exports and starts other programs after the completion of a measurement.

◆ Comply with the requirements of the 21 CFR Part 11 directive of the FDA

5100 System Kits 1 Set
5100 System Manager Integrated A/D converters Integrated A/D converters

Integrated vacuum degasser, 4 channel

Power Supply AC110/220V±10%, 50/60Hz
Optional Accessory Column Oven, Autosampler, Degasser, Diode Array Detector, Refractive Index Detector, Evaporative Light Scattering Detector, Fluorescence Detector

 