TOC Analyzer

Kategori: ALAT LABORATORIUM | 20 Kali Dilihat
TOC Analyzer Reviewed by on . This Is Article About TOC Analyzer

Features: *Signal management system with our own patent law which has great advantages of online setting, real-time monitoring, self testing and flow rate control to ensure high performance and safe operation. *Low current system design also ensures operation safety. *Different temperature setting for various samples ensures complete sample digestion so as to get more accurate measuring data. *Adjust cooling module power according to sampling volume which improves drying performance to ensure dry gas into the detector. *Automatic leakage prevention system to avoid operation mistakes and improve instrument performance, so as to ensure operation safety and instrument’s safety. *Flow rate controlling system to avoid any effect caused by flow rate fluctuation which ensures accurate data. *TOC detector with 24 bits data solution extends monitoring range. Controlling system with 32bin process- ing technology greatly improves performance. Technical Specification: Model BK-TOC-II BK-TOC-III Detector NDIR Parameters TC,TIC,TOC,NPOC Digestion High Temperature Combustion Wet Chemical Oxidation by UV Operation PC Control Application Liquid Sample,Gas Sample,Solid Sample Liquid Sample,Gas Sample Gas Requirement Oxygen/Nitrogen≥99.995% Measurement Range 0-30000mg/l   0-10000mg/l   Detection Limit 50μg/l 5μg/l Repeatability 3% Nitrogen≥99.995% Maximum Salinity 85g/l Power AC 220V,50Hz or AC 110V,60Hz Size 430*455*440mm

Rating: 1.0

Hubungi Kami

Order via SMS

6281327234498

Format SMS : ORDER#NAMA PRODUK#JUMLAH
Pemesanan Juga dapat melalui :
SKU :
Stok Tersedia
Kg
06-02-2019
Detail Produk "TOC Analyzer"

Features:

*Signal management system with our own patent law which has great advantages of online setting, real-time monitoring, self testing and flow rate control to ensure high performance and safe operation.

*Low current system design also ensures operation safety.

*Different temperature setting for various samples ensures complete sample digestion so as to get more accurate

measuring data.

*Adjust cooling module power according to sampling volume which improves drying performance to ensure dry gas

into the detector.

*Automatic leakage prevention system to avoid operation mistakes and improve instrument performance, so as to

ensure operation safety and instrument’s safety.

*Flow rate controlling system to avoid any effect caused by flow rate fluctuation which ensures accurate data.

*TOC detector with 24 bits data solution extends monitoring range. Controlling system with 32bin process- ing

technology greatly improves performance.

Technical Specification:

Model BK-TOC-II BK-TOC-III
Detector NDIR
Parameters TC,TIC,TOC,NPOC
Digestion High Temperature Combustion Wet Chemical Oxidation by UV
Operation PC Control
Application Liquid Sample,Gas Sample,Solid Sample Liquid Sample,Gas Sample
Gas Requirement Oxygen/Nitrogen≥99.995%
Measurement Range 0-30000mg/l

 

0-10000mg/l

 

Detection Limit 50μg/l 5μg/l
Repeatability 3% Nitrogen≥99.995%
Maximum Salinity 85g/l
Power AC 220V,50Hz or AC 110V,60Hz
Size 430*455*440mm

 
Chat via Whatsapp